Project Information
Background:
310,000 TPA household waste handling facility with an overall aim of producing refuse derived fuels, recover recyclables and treat organic waste.
Application:
Heat exchanger for digestion process in AD facility.
Solution:
Design, supply, install and commission 8 No Lackeby Heat exchanger; 4 sludge / sludge and 4 sludge / water, in stainless steel with external insulation and stainless steel outer cover.
Data:
Duty: 40 m3/hr
Application: 4 Sludge / Sludge
4 Sludge / Water
Objective: Maintain the average temperature at a constant 36°C even though the incoming sludge temperature would vary between 31°C and 33°C
Model Type: 4 No VSV 80-226
2 No VSV 80-222
2 No VSV 80-216
Length: 6.7 m